Floor Area Ratio (FAR) Explained: How Much Can You Build on a Plot?
Floor area ratio (FAR) is the total floor area of the buildings on a plot divided by the plot's area. To find the most floor area a plot allows, multiply the plot area by the allowed FAR: a 1,000 m² plot with a FAR of 2.0 allows 2,000 m². The real number is often lower, because ground coverage, height limits and setbacks cap what fits, so check all four together.
FAR is the first number a developer asks about and the first limit an architect designs against. This guide explains it, shows how the other rules change the answer, and how to check a real plot quickly.
What is floor area ratio?
FAR compares how much floor you build with how much land you have:
FAR = total floor area ÷ plot area
It has different names in different places, and the meaning is the same:
| Term | Where you will see it |
|---|---|
| Floor area ratio (FAR) | United States and many international codes |
| Floor space index (FSI) | India |
| Plot ratio | United Kingdom, Singapore, Hong Kong, Australia |
| Geschossflächenzahl (GFZ) | Germany |
FAR says nothing about shape. The same floor area can be one low building over the whole plot or a tower on a corner of it.

How do you calculate the buildable floor area?
- Take the plot area from the title or survey, in m² or ft².
- Find the allowed FAR for the plot's zone in the local plan or bylaws.
- Multiply: plot area × FAR = the most floor area allowed.
- Check the other limits (below) to see whether that floor area actually fits.
Try it with the free FAR calculator: enter the plot area, FAR, ground coverage and floor height, and it returns the floor area, footprint, number of floors and height.
Why is the real number often lower than FAR allows?
Because FAR is one of several limits, and the tightest one wins:
- Ground coverage caps the footprint: 40% coverage on 1,000 m² means a footprint of at most 400 m².
- Height limits cap the number of floors: at 3.2 m floor to floor, a 15 m limit allows 4 floors.
- Setbacks push the building away from the boundaries, which can shrink the footprint below the coverage limit.
- Other rules such as open space, parking, fire access or heritage controls take more.
A worked example
A 1,000 m² plot (40 m × 25 m) with FAR 2.0, coverage 40% and a height limit of 15 m:
| Step | Calculation | Result |
|---|---|---|
| Floor area allowed by FAR | 1,000 × 2.0 | 2,000 m² |
| Largest footprint | 1,000 × 40% | 400 m² |
| Floors allowed by height | 15 m ÷ 3.2 m | 4 floors |
| Floor area that fits | 400 × 4 | 1,600 m² |
| FAR you can actually reach | 1,600 ÷ 1,000 | 1.6 |
Here the height limit, not FAR, decides the scheme: 400 m² of allowed floor area cannot be built. Knowing that early changes the price you pay for the land.
What counts towards FAR?
This is where codes differ most. Depending on the place, these may be in or out:
- Basements and parking
- Balconies, terraces and covered walkways
- Stairs, lift cores and plant rooms
- Atriums and double-height spaces (counted once or twice)
Some cities also let you go above the base FAR, by buying extra floor area (premium FSI in some Indian cities, for example) or by transferring development rights from another plot. Always read your code's definitions before you trust a number.
How do you check how much you can build on a real plot?
- Search the address on UrbanEyes for a free preview of the site: surrounding buildings, ground coverage, climate and sun angles.
- Run the feasibility report. It sets out the zoning, FAR, buildable area and an indicative construction cost, with the sources it used. Jurisdiction-specific rules are built in for India, the UK, the EU, the UAE, Singapore, Japan and Thailand, and the method works for any location.
- Test massing in Plotline. Draw the building on the site and see floor area, FAR and coverage checked against the limits as you draw.
- Confirm with the authority. Use the report to brief your planning consultant or the local authority, who give the final word.
"It is perfect for planners. Site maps, feasibility and the concept planner sit in one place." Kiptum, Kenya
"I love using this. The maps, quantitative insights and feasibility report are all in one place." Jake Jadormio, Philippines
This is what makes a feasibility study more than a map: what the plot allows, what fits, and roughly what it costs, before you commit. Read more in our guide to site feasibility studies and zoning analysis.
Frequently Asked Questions
How do I calculate FAR?
Divide the total floor area of all floors by the plot area. For the reverse, multiply the plot area by the allowed FAR to get the most floor area you can build.
Is FAR the same as FSI?
Yes. Floor space index (FSI) in India, plot ratio in the UK and Singapore, and GFZ in Germany all mean floor area divided by plot area.
What does a FAR of 1.5 mean?
The total floor area may be 1.5 times the plot area: on a 2,000 m² plot, 3,000 m² of floor area, however it is stacked.
Does FAR include basements?
It depends on the code. Many codes exclude basements used for parking or services and include basements used as habitable space. Check your local definitions.
What is the difference between FAR and ground coverage?
FAR limits the total floor area on all floors. Ground coverage limits the share of the plot the building's footprint may cover. A plot can hit its coverage limit long before its FAR limit, or the other way round.

Vinayak Tiwari
Founder, UrbanEyes
Computational designer trained at IAAC Barcelona. Vinayak built every UrbanEyes product, from Site Analysis to Maps and Boards, after years of doing site studies by hand.
We analyse, you design.
Run data-backed site analysis with UrbanEyes: maps, metrics, and reports in about 15 minutes.